Home    Company Information    What's New    Contact Us   

 
Industrial Products


MODEL ANALYZER TYPE RANGES
4060 Series
Gas Chromatograph ppb levels to percent, application dependent
4040
Methane / Nonmethane Analyzer 0-10, 0-100, 0-1000 ppm


MODEL ANALYZER TYPE RANGES
6400-TSG
Total sulfur in fuel gas analyzer for gas-phase samples Trace and percent ranges available
6400-TSL
Total sulfur in liquid analyzer for diesel and gasoline Trace and percent ranges available
6200T
Total Sulfur Analyzer (in inert gases) 0-50 ppb to 0-20,000 ppb


MODEL ANALYZER TYPE RANGES
1220 & 1220-3
Multi-point combustibles analysis system for ambient detection of volatile hydrocarbons 0-100% LEL


MODEL ANALYZER TYPE RANGES
2000A
General purpose - wall or flush panel mount (typically for H2, Ar or N2) Application dependent
2000XTC
Wall mount transmitter (configured to detect H2, He, N2, Ar, CO2 or a number of other gases in binary or multi-component sample gas mixtures) Customer specified
2010
Semi-explosion proof - wall or flush panel mount control unit (typically for H2 analysis) Application dependent
2020
Fully-explosion proof, wall mount, (typically for H2 in hydrocarbon analysis) Application dependent
212R
Flush panel mount, trace thermal conductivity analyzer (typically for H2, Ar or N2) Application dependent; standard with triple range capability
2750
Portable percent TCD analyzer, designed for turbine generator applications (H2 in Air) 0-100% H2 in CO2
0-100% Air in CO2
80 - 100% H2 in Air


MODEL ANALYZER TYPE RANGES
2120
Nitrogen in Argon analyzer Model dependent, see data sheet


MODEL ANALYZER TYPE RANGES
4020
Microprocessor based total trace hydrocarbon analyzer 0-10, 0-100, 0-1000 ppm HC standard
(CH4 equivalent, lower optional ranges available)
4030
Total hydrocarbon gas analyzer heated for emissions 0-10, 0-100, 0-1000 ppm THC. Other ranges available.
4060
Benzene analyzer 0-100 ppb, 0-1 ppm, 0-10 ppm benzene
4080
Hydrocarbon in water analyzer  


MODEL ANALYZER TYPE RANGES
8800 Series
Trace moisture analysis instrumentation -100 to 20C or -65 to 20C based on sensor


MODEL ANALYZER TYPE RANGES
LXT-330 / LXT-380
Smart Transmitter and Sensors for pH, Conductivity, Resistivity, ORP, Dissolved Oxygen, Specific Ion (pION), Turbidity and Chlorine Dioxide Application specific
LXT-220, LXT-230, LXT-280
On line analysis of pH, ORP, PION, DO Conductivity & Resistivity Application specific
LXT-800
Turbidity Analyzer 0-9999 FNU, 0-3000 ppm, 0-3 g/L
LXT-220-DO8
Optical Dissolved Oxygen Analyzer 0-20 mg/L, 0-400 hPa (0-6 psi)
LXT-220-DO9
PPB Dissolved Oxygen Analyzer 0.001-20 mg/L, 0-400 hPa (0-6 psi)
FCA-220
Free Chlorine Analyzer 0-20 ppm Free Chlorine
0-14 pH
TCA-220
Total Chlorine Analyzer 0.05 to 20 ppm
4 to 12 pH
LXT-220-NH4
Ammonium Analyzer 0.1 to 1000 ppm
LXT-220-N
Nitrates Analyzer 0.1 to 1000 ppm
LXT-220-CLO2
Chlorine Dioxide Analyzer 0.05 to 20 ppm or 0.01 to 5 ppm
6650 SP
Oil-in-Water Analyzer Contact Factory
6700 TOC Series
Total Organic Carbon analyzers Analysis method specific



MODEL ANALYZER TYPE RANGES
LGA-4000 Series
Tunable Diode Laser Absorption Spectroscopy (TDLAS) applied to O2, CO, CO2, CH4, NH3, HCL, and H2Ov analysis Application / parameter dependent



MODEL ANALYZER TYPE RANGES
AN300
Hand held, portable, nitrogen analyzer 0-100 % nitrogen (100% O2%)
Transcrub
Transparent scrubber for H2S N/A


   

Home | Job Opportunities
Document Control & Training (password)
e-mail us: ask_tai@teledyne.com

Copyright 2010 Teledyne Technologies Incorporated. All rights reserved.
Teledyne Analytical Instruments • 16830 Chestnut St • City of Industry, CA 91748 • USA