Applications

  • ​​H2 cooled turbine generator
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​H2 purity
      ​Percent H2
      ​80-100%
      ​Air
      2020 TG
    • ​CO2 purge of H2 from turbine
      ​Percent CO2
      ​0-100%
      ​H2
      2020 TG
    • ​Air purge of CO2 from turbine
      ​Percent air
      ​0-100%
      ​CO2
      2020 TG
  • ​BNFL (UK)
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Nuclear fuels conversion of uranium ores to UF6
      Effluent control of fluorine
      ​Percent F2
      ​0-50%
      ​UF6, HF, O2, CF4
      6000 (UV) (commercial)
  • ​Boiler tube control
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Oil in boiler return steam condensate
      ​PPM oil
      ​0-10 ppm
      ​Condensate
  • ​Combustion Efficiency
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​​Stack gas analysis
      ​PPM CO
      ​0-1,000 ppm

      -​

  • ​Cooling water
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Hydrocarbons in cooling H2O
      ​PPM hydrocarbons
      ​0-10 ppm
      ​ Water
  • ​Desalination Plant
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Seawater electro chlorination unit efficiency performance
      ​PPM NaOCL (hypochlorite ion)
      ​0-1,500 pm
      ​Seawater
      6000 (UV)
  • ​Excess O2
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​​Stack gas analysis
      ​Percent O2
      ​0-5%
      ​​Flue gas
      9060Z (ZrO2) On-line / Continuous
  • ​Excess O2 / Boiler
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Stack gas analysis
      ​Percent O2
      ​Percent O2; PPM CO comb
      ​0-5%
      ​See data sheet
      ​Flue gas
      3110P PEM-9004 Portable Analyzers
  • ​Flue Gas Desulfurization (FGD)
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Inlet to fluidized bed / absorber
      ​Percent SO2
      ​0-1%
      ​Flue gas
      6000 (UV)
    • ​Outlet from fluidized bed / absorber
      ​PPM SO2
      ​0-250, 0-500 ppm
      ​Flue gas
      6000 (UV)
  • ​H2 Turbine generator​
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​H2 purity / turbine maintenance
      ​Percent H2, CO2, Air
      ​See data sheet
      ​Air, H2, CO2
  • ​KEPCO - Korea
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Gaseous waste treatment
      ​Percent O2
      ​0-5, 0-10%
      ​N2
      3000MA (commercial)
    • ​Deuterium (D2) in air
      ​Percent D2
      ​0-5%
      ​Air
      2000A (commercial)
  • ​Pollution Abatement
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Continuous Emission Monitor
      ​PPM SO2
      ​0-250 to 0-5,000 ppm
      ​Flue gas
      6000 (UV)
    • ​CEM / Stack Gas
      ​PPM NOX
      ​0-10 to 0-5,000 ppm
      ​Flue gas
      9110TH Chemiluminescence
    • ​Stack gas analysis
      ​Percent O2; PPM CO, SO2, NO, NO2; Percent CO2
      ​See data sheet
      ​Flue gas
      NA PEM-9004 Portable Analyzers
  • ​SF6 Filling
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Electrical apparatus / switchbox
      ​PPM O2
      ​0-10 ppm
      ​SFG
  • ​Vacuum Drag System
    • Service
      Parameter(s)
      Range(s)
      Background
      Model
      ​Recombiner (after condenser)
      ​Percent H2
      ​0-5% H2
      ​O2 / N2
      2000A (commercial)
    • ​Feed to off gas compressors aka Catalytic recomber of radwaste gas mixture
      ​Percent O2
      ​0-5% O2
      ​N2 / H2
      3000MA (commercial)