TAI Gas Products

  • Carbon Dioxide Systems
    • Model
      Image
      Description
      Gases/Detectors
      ​CDQC​​
      Carbon Dioxide Quality Control System​​


      Carbon Dioxide (CO2) Purity
      Acetaldehyde (C2H4O)
      Ammonia (NH3) Aromatic Hydrocarbon Benzene (C6H6) Carbon Monoxide (CO) Methanol (CH3OH) Moisture (H2Ov)
      Nitric Oxide (NO) Nitrogen Dioxide (NO2) Oxygen (O2)
      Sulfur Dioxide (SO2) Total Sulfur
      Total Volatile
      Hydrocarbons​
  • Gas Chromatographs
    • Model
      Image
      Description
      Gases/Detectors
      ​Falcon-GC​

      Ultra-Fast Gas Chromatograph for Process and Lab Applications
      •Aspiration to inlet via sample pump
      •Process online via sample valve for gas or liquid*
      •Autosampler injections for liquid or heated headspace
      •Manual syringe injection for gas or liquid

      *Sample handling available​

      Dielectric Barrier Discharge (DBD) Flame Ionization (FID)
      Flame Photometric (FPD) Thermal Conductivity (TCD)​


    • ​4000-Series
      Ultra-Fast Rack-Mount Gas Chromatograph​

      Dielectric Barrier Discharge (DBD)
      Flame Ionization (FID)​
    • ​4040
      Process online via sample valve for gas and aspiration​

      ​Flame Photometric (FPD) Thermal Conductivity (TCD)​
    • ​4060​
      Methane / Non-Methane Gas Chromatograph​

      Flame Ionization (FID)​
  • Hydrocarbon Analyzers
    • Model
      Image
      Description
      Range
      4020
      Total Hydrocarbon Analyze​
      0-10, 0-100, 0-1,000 ppm THC​
    • ​4030
      Total Hydrocarbon Analyzer semi-continuous for heated or ambient samples​
      standard​
  • Infrared Analyzers
    • Model
      Image
      Gases/Detectors
      Technology
      Range
      ​7500ZA

      Carbon Dioxide(CO2)
      Carbon Monoxide (CO)
      Methane (CH4)
      Nitric Oxide (NO)
      Oxygen (O2) (fuel cell)
      Oxygen (O2)
      (paramagnetic)
      Sulfur Dioxide (SO2)​


      Non-Dispersive Infrared (NDIR)

      0-100 ppm to 0-100%
      0-200 ppm to 0-100%
      0-500 ppm to 0-100%
      0-200 ppm to 0-5,000 ppm
      0-10% to 0-25%
      0-5% to 0-100% (7500ZA)
      0-200 ppm to 0-10%​




    • ​7600ZA

      Carbon Dioxide(CO2)
      Carbon Monoxide (CO)
      Methane (CH4)
      Nitric Oxide (NO)
      Oxygen (O2) (fuel cell)
      Oxygen (O2)
      (paramagnetic)
      Sulfur Dioxide (SO2)​


      Non-Dispersive Infrared (NDIR)

      0-50 ppm to 0-25%
      0-50 ppm to 0-5,000 ppm
      0-50 ppm to 0-5,000 ppm
      0-10% to 0-25%
      0-5% to 0-100%
      0-50 ppm to 0-5,000 ppm​


    • ​GFC-7000T
      Carbon Dioxide (CO2)​
      Infrared Absorption with Gas Filter Correlation

      0-2 ppm to 0-2,000 ppm
      (0-100 ppb to 0-100 ppm
      for -U version)
      (dual ranges and auto
      ranging supported)​


    • ​GFC-7001T
      Carbon Monoxide (CO)​
      Infrared Absorption with Gas Filter Correlation

      0-1 ppm to 0-1,000 ppm
      (0-100ppb to 0-100ppm
      for-U version)
      (dual ranges and auto
      ranging supported)​


    • ​GFC-7002T​
      Nitrous Oxide (N2O)​
      Infrared Absorption with Gas Filter Correlation

      0-1 ppm to 0-1,000 ppm
      (0-200 ppb to 0-200 ppm
      for -U version)
      (dual ranges and auto
      ranging supported)​


  • Moisture Analyzers
    • Model
      Image
      Technology
      Range
      8800A​
      Aluminum Oxide (Al2O3)
      -100°C to +20°C dew-point​
    • ​8800B​​
      Aluminum Oxide (Al2O3)
      -100°C to +20°C dew-point​
    • 8800P
      Aluminum Oxide (Al2O3)
      -100°C to +20°C dew-point​
    • ​8800T
      Aluminum Oxide (Al2O3)
      -100°C to +20°C dew-point​
  • Nitrogen Analyzer
    • Model
      Image
      Technology
      Range
      2120XL
      Plasma Ionization

      0-1, 0-10, 0-100 ppm user-settable, fixed or auto-ranging
      Higher ranges optional​


  • Nitrogen Oxides (NOx) & Ammonia Analyzers
    • Model
      Image
      Gases/Detectors
      Technology
      Range
      9110T​​

      Nitrogen Dioxide (NO2)
      Nitric Oxide (NO)
      Nitrogen Oxides (NOX) Optional Oxygen (O2) with paramagnetic sensor​


      Chemiluminescence

      ​0-50 ppb (min)
      0-20,000 ppb (max)
      (selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX) ranges and auto-ranging supported)​
    • ​9110TH​

      Nitrogen Dioxide (NO2)
      Nitric Oxide (NO)
      Nitrogen Oxides (NOX) Optional Oxygen (O2) with paramagnetic sensor​


      Chemiluminescence

      0-5 ppm (min)
      0-5,000 ppm (max)
      (selectable, independent Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxide (NOX)​ ranges and auto-ranging supported)​
  • Oxygen Analyzers (Fixed)
    • Model
      Image
      Technology
      Range
      3000RS-P

      M​icro-Fuel Cell (Percent)

      M​in: 0-1% Max: 0-100%

    • 3000RS-T

      M​icro-Fuel Cell (PPM)

      M​in: 0-10 ppm Max: 0-10,000 ppm​​​​

    • 3000RS-TXL

      M​icro-Fuel Cell (PPM)



      M​in: 0-1 ppm Max: 0-10,000 ppm​​​



    • 3000MA
      Paramagnetic
      0-5% to 0-100%
      Calibration: 0-25%​
    • ​3000PA​
      Micro-Fuel Cell (Percent)​​
      0-1% (min), 0-100% (max) Calibration: 0-25%
    • ​3000TA​
      Micro-Fuel Cell (PPM)​​
      0-1% (min), 0-100% (max) Calibration: 0-25%
    • ​3000TA-XL​
      Micro-Fuel Cell (PPM)​​


      3 range customer selectable
      (Minimum 0-1 ppm FS)​

    • 3000MB
      Paramagnetic
      0-5% to 0-100% Calibration: 0-25%
    • ​3000PB​
      Micro-Fuel Cell (Percent)​​
      0-1% (min), 0-100% (max) Calibration: 0-25%
    • ​3000TB​
      Micro-Fuel Cell (Percent)​​
      0-1% (min), 0-100% (max) Calibration: 0-25%
    • ​3010MA​​​
      Micro-Fuel Cell (PPM)​​
      90-100% O2 95-100% O2 98-100% O2 Other ranges available
    • ​3010PAC​
      Micro-Fuel Cell (PPM)​​
      Min: 0-1% Max: 0-100%
    • ​3010TAC​
      Micro-Fuel Cell (Percent)​​
      0-10 ppm (min), 0-9,999 ppm (max) Calibration: 0-25%
    • ​3010PBC​
      Micro-Fuel Cell (PPM)​​
      Min: 0-1% Max: 0-100%
    • ​3010TBC​
      Micro-Fuel Cell (PPM)

      0-10 ppm (min), 0-9,999 ppm (max)
      Calibration: 0-25%​


    • ​3020M​
      Explosion Proof Paramagnetic
      0-5% to 0-100%​
    • ​3020P​
      Explosion Proof Percent

      0-1% (min), 0-100% (max)
      Calibration: 0-25%​


    • ​3020T​
      Micro-Fuel Cell (PPM)

      0-10 ppm (min), 0-9,999 ppm (max)
      Calibration: 0-25%​


    • ​3190​
      Trace
      0-10 ppm to 0-9,999 ppm Calibration: 0-25%
    • ​3290​
      Percent
      0-1% to 0-25% (optional 0-100%)​


    • ​3300TA​
      Micro-Fuel Cell (PPM)

      Two ranges with auto ranging capability
      Field configurable:
      0-10ppm to 0-10,000ppm​

    • ​3300TB​
      Micro-Fuel Cell (PPM)

      Two ranges with auto ranging capability
      Field configurable:
      0-10ppm to 0-10,000ppm​

    • ​3350​
      Micro-Fuel Cell
      0-25% oxygen​
    • ​9060Z​
      Zirconium Oxide (ZrO2)
      0.01 ppm to 100%​
    • InstaTrans-XD​
      Micro-fuel Cell (Percent or ppm)
      0-10 ppm to 0-25%​
  • Oxygen Analyzers (Portable)
    • Model
      Image
      Technology
      Range
      ​3110​
      Micro-fuel Cell (Trace / Percent)

      0-10 ppm to 0-25%*
      *third-party approved only for O2 levels below 20.9%​


    • ​3110P​
      Micro-fuel Cell (Percent)

      0-1% to 0-25%*
      (optional 0-100%*)
      *third-party approved only for O2 levels below 20.9%​


    • ​3110XL​
      Micro-fuel Cell (Trace / Percent)

      0-2 ppm to 0-25%*
      *third-party approved only for O2 levels below 20.9%​


  • Sulfur Analyzers
    • Model
      Image
      Gases/Detectors
      Technology
      Range
      6200T​
      Total Sulfur
      UV-Fluorescence

      0-50 ppb (min)
      0-20,000 ppb (max)​​


    • 6400T​
      Sulfur Dioxide (SO2)
      UV-Fluorescence

      0-50 ppb (min)
      0-20,000 ppb (max)​


    • ​6400TH​
      Sulfur Dioxide (SO2)
      UV-Fluorescence

      0-10 ppm (min)
      0-5,000 ppm (max)​


    • ​6400TSG​
      Total Sulfur
      UV-Fluorescence

      PPB to percent levels,
      application specific​


  • Thermal Conductivity Analyzers
    • Model
      Image
      Technology
      Range
      2000RS


      ​Thermal Conductivity Analyzers

      P​er application
    • 2000A
      Thermal Conductivity Analyzers
      Per application​
    • ​2000B​
      Thermal Conductivity Analyzers
      Per application​
    • ​2000XTC​
      Thermal Conductivity Analyzers
      Per application​
    • ​2020​
      Thermal Conductivity Analyzers
      Per application​
    • 2750​
      Thermal Conductivity Analyzers


      0-100% H2 in CO2
      0-100% Air in CO2
      80-100% H2 in Air​

  • Tunable Diode Laser (TDL) Analyzer
    • Model
      Image
      Gases/Detectors
      Technology
      Range
      LGA-4000Z​

      Acetylene (C2H2)
      Ammonia (NH3)
      Carbon Dioxide
      (CO2)
      Carbon Monoxide
      (CO)
      Ethylene (C2H4)
      Hydrogen Chloride
      (HCl)
      Hydrofluoric Acid
      (HF)
      Hydrogen Sulfide
      (H2S)
      Methane (CH4)
      Oxygen (O2)
      Water (H2O)​


      Tunable Diode Laser Spectroscopy (TDLAS)

      0-50 ppm to 0-100%
      0-10 ppm to 0-100%
      0-1,000 ppm to 0-
      100%
      0-1,000 ppm to 0-
      100%
      0-100 ppm to 0-100%
      0-100 ppm to 0-50%
      0-20 ppm to 0-50%
      0-100 ppm to 0-100%
      0-200 ppm to 0-100%
      0-1% to 0-25%
      0-100 ppm to 0-100%​


  • Ultraviolet Analyzers
    • Model
      Image
      Gases/Detectors
      Technology
      Range
      6200T​​
      Total Sulfur
      UV-Fluorescence

      0-50 ppb (min)
      0-20,000 ppb (max)​


    • ​6400T​
      Sulfur Dioxide (SO2)
      UV-Fluorescence

      0-50 ppb (min)
      0-20,000 ppb (max)​


    • ​6400TH​
      Sulfur Dioxide (SO2)
      UV-Fluorescence

      0-10 ppm (min)
      0-5,000 ppm (max)​


TAI Liquid Products

  • Alkalinity Analyzer
    • Model
      6800T​
  • Ammonia / Ammonium Analyzer
    • Model
      LXT-​330-NH4​
  • Chlorine Analyzers
    • Model
      ​CDA330
    • FCA330​
    • TCA​330​
  • Colorimeter
    • Model
      CA​600​​
  • Conductivity
    • Model
      LXT-330​
    • ​LXT-380​​
  • Hydrocarbon in Water Analyzers
    • Model
      4080​​
    • 6650SP​
    • 6700E
    • 6700U
  • Liquid Chromatography
    • Model
      Falcon GC​
  • Nitrates Analyzer
    • Model
      LXT-330-N
  • Oil-in-water Analyzers
    • Model
      4080
    • 6650SP​​
    • ​6700E​
    • 6700U
  • Organics Analyzer
    • Model
      6700U
  • Oxydation Reduction Potential (ORP)
    • Model
      LXT-330
    • LXT-380
  • Oxygen Dissolved Analyzers (DO)
    • Model
      LXT-330
    • ​LXT-380​
  • pH Analyzers
    • Model
      LXT-330
    • ​LXT-380​
  • Suspended Solids / Turbidity Analyzer
    • Model
      LXT-330
  • Total Organic Carbon Analyzers
    • Model
      6700E
    • ​6700U
  • Water Cut / BS&W
    • Model
      5650

TAI Oxygen Sensors

  • Automotive Sensors
    • Class
      Image
      Application
      R-17A​​
      The "R" series of sensors are used by most automotive emission equipment manufacturers worldwide.​
    • ​R-21A​​
      The "R" series of sensors are used by most automotive emission equipment manufacturers worldwide.​
    • ​R-22A​​
      The "R" series of sensors are used by most automotive emission equipment manufacturers worldwide.​
  • Diving Sensors
    • Class
      Image
      Application
      R-17S
      R-17S
      Cylinder blend checking for sports diving with minim phone jack connector​
    • R-22S
      R-22S
      Cylinder blend checking for sports diving with Molex 3-pin connector​
    • R-33S
      R-33S
      High output for driving LCD directly in small, handheld instruments​
    • R-33S-1
      R-33S-1
      High output for driving LCD directly in small, handheld instruments​
  • Medical Sensors
    • Class
      Image
      Application
      C-1R
      C-1R
      *The FDA requires that the end user is a medical facility by registration or license​
    • C-2R
      C-2R
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-15
      R-15
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-17MED
      R-17MED
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-22MED
      R-22MED
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-23
      R-23
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-24MED
      R-24MED
      *The FDA requires that the end user is a medical facility by registration or license​
    • R-36MED
      R-36MED
      *The FDA requires that the end user is a medical facility by registration or license​
    • T-1
      T-1
      *The FDA requires that the end user is a medical facility by registration or license​
    • T-2
      T-2
      *The FDA requires that the end user is a medical facility by registration or license​
    • T-7
      T-7
      *The FDA requires that the end user is a medical facility by registration or license​
    • UFO-130-2
      UFO-130-2
      *The FDA requires that the end user is a medical facility by registration or license​
  • Sensors for Oxygen Analyzers
    • Class
      Image
      Application
      A-2C​​
      A-2C​​
      ​Used for trace Oxygen (O2) measurements in Carbon Dioxide (CO2) containing backgrounds (0.1-100% CO2). CO2 mustbe present​
    • A-2CXL
      A-2CXL
      Specially qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm​
    • A-5​​
      A-5​​
      Intermittent or continuous monitoring of percent Oxygen (O2) in gas mixtures containing 0-100% Carbon Dioxide (CO2). 90% response time is 45 seconds​
    • B1
      B1
      General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds)​
    • ​B-1C
      ​B-1C
      General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds)​
    • ​B-2C​​
      ​B-2C​​
      General purpose trace Oxygen (O2) analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm.​
    • ​B-2CXL​
      ​B-2CXL​
      Specially qualified B-2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm.​
    • ​B-3
      ​B-3
      Percent Oxygen (O2) analysis, best compromise between long life and fast response​
    • E​-2​​
      E​-2​​
      Long life cell for use is the model 3290 (for use in unattended air liquefaction nitrogen skids)​
    • ​InstaTrace​
      Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes.​
    • ​InstaTrace
      Instatrace-CO2 - Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes​​​
    • ​InstaTrace
      Instatrace-XL - Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes.​​
    • ​L-2C​
      ​L-2C​
      Used for general purpose trace oxygen analysis in the 3000T analyzer series​